Error Codes
On this page you can see all the error codes the SLT machine can show and how to act upon them. You can also download them in a PDF file.

Error codes
Error message 201/202
The pressure during vacuuming of the measurement space does not reach a set value within a set time.
Cause:
- Pack leak / Big hole or
- Membrane has a leak
Big leak (error message in logfile 101 or error 102)
The measurement is checked and is above a set value.
Cause:
- Big hole in the pack or
- Membrane has a leak
Error 203
Main valve did not function properly.
Contact Oxipack support
Sensor error
Sensor has no signal.
Contact Oxipack support
Air pressure below 4 bar
Please verify incoming pressure and follow instructions on the display. Once the feed pressure reached the
correct value, instructions will appear.